Impact of Contaminated Fluid on the Working Performances of Hydraulic Directional Control Valve

3367 Ogledov
2331 Prenosov
Izvoz citacije: ABNT
KARANOVIĆ, Velibor ;JOCANOVIĆ, Mitar ;BALOŠ, Sebastian ;KNEŽEVIĆ, Darko ;MAČUŽIĆ, Ivan .
Impact of Contaminated Fluid on the Working Performances of Hydraulic Directional Control Valve. 
Strojniški vestnik - Journal of Mechanical Engineering, [S.l.], v. 65, n.3, p. 139-147, march 2019. 
ISSN 0039-2480.
Available at: <https://www.sv-jme.eu/sl/article/impact-of-contaminated-fluid-on-working-performances-of-hydraulic-directional-control-valve/>. Date accessed: 15 oct. 2024. 
doi:http://dx.doi.org/10.5545/sv-jme.2018.5856.
Karanović, V., Jocanović, M., Baloš, S., Knežević, D., & Mačužić, I.
(2019).
Impact of Contaminated Fluid on the Working Performances of Hydraulic Directional Control Valve.
Strojniški vestnik - Journal of Mechanical Engineering, 65(3), 139-147.
doi:http://dx.doi.org/10.5545/sv-jme.2018.5856
@article{sv-jmesv-jme.2018.5856,
	author = {Velibor  Karanović and Mitar  Jocanović and Sebastian  Baloš and Darko  Knežević and Ivan  Mačužić},
	title = {Impact of Contaminated Fluid on the Working Performances of Hydraulic Directional Control Valve},
	journal = {Strojniški vestnik - Journal of Mechanical Engineering},
	volume = {65},
	number = {3},
	year = {2019},
	keywords = {hydraulic systems, condition monitoring, tribology, wear},
	abstract = {The study aims to investigate the impact of solid particles on the directional hydraulic valve operation. Experiments have been performed for a certain number of operating cycles to measure the impact of the working fluid cleanliness level on the intensity of the wear on contact surfaces as well as on other failures in the operation of the directional control valve. For experimental purposes, a mechanically actuated control valve 4/2 is used. The wear intensity of working elements was determined for different levels of oil contamination by solid particles. Also, experimental results have shown that there are differences between theoretically calculated and the measured flow through the radial clearance. By measuring pressure drop values during the fluid flow through the valve, it was found that oils with the lowest cleanliness level have a greater dispersion of the measured values. The results will contribute to better understanding the impact of working fluid cleanliness on possible defects and failures happening inside hydraulic system components.},
	issn = {0039-2480},	pages = {139-147},	doi = {10.5545/sv-jme.2018.5856},
	url = {https://www.sv-jme.eu/sl/article/impact-of-contaminated-fluid-on-working-performances-of-hydraulic-directional-control-valve/}
}
Karanović, V.,Jocanović, M.,Baloš, S.,Knežević, D.,Mačužić, I.
2019 March 65. Impact of Contaminated Fluid on the Working Performances of Hydraulic Directional Control Valve. Strojniški vestnik - Journal of Mechanical Engineering. [Online] 65:3
%A Karanović, Velibor 
%A Jocanović, Mitar 
%A Baloš, Sebastian 
%A Knežević, Darko 
%A Mačužić, Ivan 
%D 2019
%T Impact of Contaminated Fluid on the Working Performances of Hydraulic Directional Control Valve
%B 2019
%9 hydraulic systems, condition monitoring, tribology, wear
%! Impact of Contaminated Fluid on the Working Performances of Hydraulic Directional Control Valve
%K hydraulic systems, condition monitoring, tribology, wear
%X The study aims to investigate the impact of solid particles on the directional hydraulic valve operation. Experiments have been performed for a certain number of operating cycles to measure the impact of the working fluid cleanliness level on the intensity of the wear on contact surfaces as well as on other failures in the operation of the directional control valve. For experimental purposes, a mechanically actuated control valve 4/2 is used. The wear intensity of working elements was determined for different levels of oil contamination by solid particles. Also, experimental results have shown that there are differences between theoretically calculated and the measured flow through the radial clearance. By measuring pressure drop values during the fluid flow through the valve, it was found that oils with the lowest cleanliness level have a greater dispersion of the measured values. The results will contribute to better understanding the impact of working fluid cleanliness on possible defects and failures happening inside hydraulic system components.
%U https://www.sv-jme.eu/sl/article/impact-of-contaminated-fluid-on-working-performances-of-hydraulic-directional-control-valve/
%0 Journal Article
%R 10.5545/sv-jme.2018.5856
%& 139
%P 9
%J Strojniški vestnik - Journal of Mechanical Engineering
%V 65
%N 3
%@ 0039-2480
%8 2019-03-27
%7 2019-03-27
Karanović, Velibor, Mitar  Jocanović, Sebastian  Baloš, Darko  Knežević, & Ivan  Mačužić.
"Impact of Contaminated Fluid on the Working Performances of Hydraulic Directional Control Valve." Strojniški vestnik - Journal of Mechanical Engineering [Online], 65.3 (2019): 139-147. Web.  15 Oct. 2024
TY  - JOUR
AU  - Karanović, Velibor 
AU  - Jocanović, Mitar 
AU  - Baloš, Sebastian 
AU  - Knežević, Darko 
AU  - Mačužić, Ivan 
PY  - 2019
TI  - Impact of Contaminated Fluid on the Working Performances of Hydraulic Directional Control Valve
JF  - Strojniški vestnik - Journal of Mechanical Engineering
DO  - 10.5545/sv-jme.2018.5856
KW  - hydraulic systems, condition monitoring, tribology, wear
N2  - The study aims to investigate the impact of solid particles on the directional hydraulic valve operation. Experiments have been performed for a certain number of operating cycles to measure the impact of the working fluid cleanliness level on the intensity of the wear on contact surfaces as well as on other failures in the operation of the directional control valve. For experimental purposes, a mechanically actuated control valve 4/2 is used. The wear intensity of working elements was determined for different levels of oil contamination by solid particles. Also, experimental results have shown that there are differences between theoretically calculated and the measured flow through the radial clearance. By measuring pressure drop values during the fluid flow through the valve, it was found that oils with the lowest cleanliness level have a greater dispersion of the measured values. The results will contribute to better understanding the impact of working fluid cleanliness on possible defects and failures happening inside hydraulic system components.
UR  - https://www.sv-jme.eu/sl/article/impact-of-contaminated-fluid-on-working-performances-of-hydraulic-directional-control-valve/
@article{{sv-jme}{sv-jme.2018.5856},
	author = {Karanović, V., Jocanović, M., Baloš, S., Knežević, D., Mačužić, I.},
	title = {Impact of Contaminated Fluid on the Working Performances of Hydraulic Directional Control Valve},
	journal = {Strojniški vestnik - Journal of Mechanical Engineering},
	volume = {65},
	number = {3},
	year = {2019},
	doi = {10.5545/sv-jme.2018.5856},
	url = {https://www.sv-jme.eu/sl/article/impact-of-contaminated-fluid-on-working-performances-of-hydraulic-directional-control-valve/}
}
TY  - JOUR
AU  - Karanović, Velibor 
AU  - Jocanović, Mitar 
AU  - Baloš, Sebastian 
AU  - Knežević, Darko 
AU  - Mačužić, Ivan 
PY  - 2019/03/27
TI  - Impact of Contaminated Fluid on the Working Performances of Hydraulic Directional Control Valve
JF  - Strojniški vestnik - Journal of Mechanical Engineering; Vol 65, No 3 (2019): Strojniški vestnik - Journal of Mechanical Engineering
DO  - 10.5545/sv-jme.2018.5856
KW  - hydraulic systems, condition monitoring, tribology, wear
N2  - The study aims to investigate the impact of solid particles on the directional hydraulic valve operation. Experiments have been performed for a certain number of operating cycles to measure the impact of the working fluid cleanliness level on the intensity of the wear on contact surfaces as well as on other failures in the operation of the directional control valve. For experimental purposes, a mechanically actuated control valve 4/2 is used. The wear intensity of working elements was determined for different levels of oil contamination by solid particles. Also, experimental results have shown that there are differences between theoretically calculated and the measured flow through the radial clearance. By measuring pressure drop values during the fluid flow through the valve, it was found that oils with the lowest cleanliness level have a greater dispersion of the measured values. The results will contribute to better understanding the impact of working fluid cleanliness on possible defects and failures happening inside hydraulic system components.
UR  - https://www.sv-jme.eu/sl/article/impact-of-contaminated-fluid-on-working-performances-of-hydraulic-directional-control-valve/
Karanović, Velibor, Jocanović, Mitar, Baloš, Sebastian, Knežević, Darko, AND Mačužić, Ivan.
"Impact of Contaminated Fluid on the Working Performances of Hydraulic Directional Control Valve" Strojniški vestnik - Journal of Mechanical Engineering [Online], Volume 65 Number 3 (27 March 2019)

Avtorji

Inštitucije

  • University of Novi Sad, Faculty of Technical Sciences 1
  • University of Banja Luka, Faculty of Mechanical Engineering 2
  • University of Kragujevac, Faculty of Engineering 3

Informacije o papirju

Strojniški vestnik - Journal of Mechanical Engineering 65(2019)3, 139-147
© The Authors, CC-BY 4.0 Int. Change in copyright policy from 2022, Jan 1st.

https://doi.org/10.5545/sv-jme.2018.5856

The study aims to investigate the impact of solid particles on the directional hydraulic valve operation. Experiments have been performed for a certain number of operating cycles to measure the impact of the working fluid cleanliness level on the intensity of the wear on contact surfaces as well as on other failures in the operation of the directional control valve. For experimental purposes, a mechanically actuated control valve 4/2 is used. The wear intensity of working elements was determined for different levels of oil contamination by solid particles. Also, experimental results have shown that there are differences between theoretically calculated and the measured flow through the radial clearance. By measuring pressure drop values during the fluid flow through the valve, it was found that oils with the lowest cleanliness level have a greater dispersion of the measured values. The results will contribute to better understanding the impact of working fluid cleanliness on possible defects and failures happening inside hydraulic system components.

hydraulic systems, condition monitoring, tribology, wear