Mechanical and Structural Analyses Supporting the Steam-Generator Replacement and Power Uprating at the Krško NPP

1812 Ogledov
975 Prenosov
Izvoz citacije: ABNT
KRAJNC, Božidar ;ŽUPEC, Janez .
Mechanical and Structural Analyses Supporting the Steam-Generator Replacement and Power Uprating at the Krško NPP. 
Strojniški vestnik - Journal of Mechanical Engineering, [S.l.], v. 46, n.4, p. 214-229, july 2017. 
ISSN 0039-2480.
Available at: <https://www.sv-jme.eu/sl/article/mechanical-and-structural-analyses-supporting-the-steam-generator-replacement-and-power-uprating-at-the-krsko-npp/>. Date accessed: 25 apr. 2024. 
doi:http://dx.doi.org/.
Krajnc, B., & Župec, J.
(2000).
Mechanical and Structural Analyses Supporting the Steam-Generator Replacement and Power Uprating at the Krško NPP.
Strojniški vestnik - Journal of Mechanical Engineering, 46(4), 214-229.
doi:http://dx.doi.org/
@article{.,
	author = {Božidar  Krajnc and Janez  Župec},
	title = {Mechanical and Structural Analyses Supporting the Steam-Generator Replacement and Power Uprating at the Krško NPP},
	journal = {Strojniški vestnik - Journal of Mechanical Engineering},
	volume = {46},
	number = {4},
	year = {2000},
	keywords = {integrity; mechanical analysis; structural analysis; leak before break (LBB); },
	abstract = {Krško nuclear power plant (NPP) is one of the last pressurized water reactor NPPs of western design in Europe, which has decided to replace the existing steam generators and at the same time perform a power uprating. A comprehensive set of design calculations and safety analyses have been performed to demonstrate: - that the new steam generators are compatible with the existing plant, - that the plant can operate safely and with adequate margins at the uprated power. In this paper only the mechanical and structural analyses are presented. These analyses meet, as verified by independent evaluations, high quality standards and ensure the safe operation of Krško NPP after the replacement of the steam generators and the power uprating.},
	issn = {0039-2480},	pages = {214-229},	doi = {},
	url = {https://www.sv-jme.eu/sl/article/mechanical-and-structural-analyses-supporting-the-steam-generator-replacement-and-power-uprating-at-the-krsko-npp/}
}
Krajnc, B.,Župec, J.
2000 July 46. Mechanical and Structural Analyses Supporting the Steam-Generator Replacement and Power Uprating at the Krško NPP. Strojniški vestnik - Journal of Mechanical Engineering. [Online] 46:4
%A Krajnc, Božidar 
%A Župec, Janez 
%D 2000
%T Mechanical and Structural Analyses Supporting the Steam-Generator Replacement and Power Uprating at the Krško NPP
%B 2000
%9 integrity; mechanical analysis; structural analysis; leak before break (LBB); 
%! Mechanical and Structural Analyses Supporting the Steam-Generator Replacement and Power Uprating at the Krško NPP
%K integrity; mechanical analysis; structural analysis; leak before break (LBB); 
%X Krško nuclear power plant (NPP) is one of the last pressurized water reactor NPPs of western design in Europe, which has decided to replace the existing steam generators and at the same time perform a power uprating. A comprehensive set of design calculations and safety analyses have been performed to demonstrate: - that the new steam generators are compatible with the existing plant, - that the plant can operate safely and with adequate margins at the uprated power. In this paper only the mechanical and structural analyses are presented. These analyses meet, as verified by independent evaluations, high quality standards and ensure the safe operation of Krško NPP after the replacement of the steam generators and the power uprating.
%U https://www.sv-jme.eu/sl/article/mechanical-and-structural-analyses-supporting-the-steam-generator-replacement-and-power-uprating-at-the-krsko-npp/
%0 Journal Article
%R 
%& 214
%P 16
%J Strojniški vestnik - Journal of Mechanical Engineering
%V 46
%N 4
%@ 0039-2480
%8 2017-07-07
%7 2017-07-07
Krajnc, Božidar, & Janez  Župec.
"Mechanical and Structural Analyses Supporting the Steam-Generator Replacement and Power Uprating at the Krško NPP." Strojniški vestnik - Journal of Mechanical Engineering [Online], 46.4 (2000): 214-229. Web.  25 Apr. 2024
TY  - JOUR
AU  - Krajnc, Božidar 
AU  - Župec, Janez 
PY  - 2000
TI  - Mechanical and Structural Analyses Supporting the Steam-Generator Replacement and Power Uprating at the Krško NPP
JF  - Strojniški vestnik - Journal of Mechanical Engineering
DO  - 
KW  - integrity; mechanical analysis; structural analysis; leak before break (LBB); 
N2  - Krško nuclear power plant (NPP) is one of the last pressurized water reactor NPPs of western design in Europe, which has decided to replace the existing steam generators and at the same time perform a power uprating. A comprehensive set of design calculations and safety analyses have been performed to demonstrate: - that the new steam generators are compatible with the existing plant, - that the plant can operate safely and with adequate margins at the uprated power. In this paper only the mechanical and structural analyses are presented. These analyses meet, as verified by independent evaluations, high quality standards and ensure the safe operation of Krško NPP after the replacement of the steam generators and the power uprating.
UR  - https://www.sv-jme.eu/sl/article/mechanical-and-structural-analyses-supporting-the-steam-generator-replacement-and-power-uprating-at-the-krsko-npp/
@article{{}{.},
	author = {Krajnc, B., Župec, J.},
	title = {Mechanical and Structural Analyses Supporting the Steam-Generator Replacement and Power Uprating at the Krško NPP},
	journal = {Strojniški vestnik - Journal of Mechanical Engineering},
	volume = {46},
	number = {4},
	year = {2000},
	doi = {},
	url = {https://www.sv-jme.eu/sl/article/mechanical-and-structural-analyses-supporting-the-steam-generator-replacement-and-power-uprating-at-the-krsko-npp/}
}
TY  - JOUR
AU  - Krajnc, Božidar 
AU  - Župec, Janez 
PY  - 2017/07/07
TI  - Mechanical and Structural Analyses Supporting the Steam-Generator Replacement and Power Uprating at the Krško NPP
JF  - Strojniški vestnik - Journal of Mechanical Engineering; Vol 46, No 4 (2000): Strojniški vestnik - Journal of Mechanical Engineering
DO  - 
KW  - integrity, mechanical analysis, structural analysis, leak before break (LBB), 
N2  - Krško nuclear power plant (NPP) is one of the last pressurized water reactor NPPs of western design in Europe, which has decided to replace the existing steam generators and at the same time perform a power uprating. A comprehensive set of design calculations and safety analyses have been performed to demonstrate: - that the new steam generators are compatible with the existing plant, - that the plant can operate safely and with adequate margins at the uprated power. In this paper only the mechanical and structural analyses are presented. These analyses meet, as verified by independent evaluations, high quality standards and ensure the safe operation of Krško NPP after the replacement of the steam generators and the power uprating.
UR  - https://www.sv-jme.eu/sl/article/mechanical-and-structural-analyses-supporting-the-steam-generator-replacement-and-power-uprating-at-the-krsko-npp/
Krajnc, Božidar, AND Župec, Janez.
"Mechanical and Structural Analyses Supporting the Steam-Generator Replacement and Power Uprating at the Krško NPP" Strojniški vestnik - Journal of Mechanical Engineering [Online], Volume 46 Number 4 (07 July 2017)

Avtorji

Inštitucije

  • Nuclear Power Plant Krško, Slovenia
  • Nuclear Power Plant Krško, Slovenia

Informacije o papirju

Strojniški vestnik - Journal of Mechanical Engineering 46(2000)4, 214-229
© The Authors, CC-BY 4.0 Int. Change in copyright policy from 2022, Jan 1st.

Krško nuclear power plant (NPP) is one of the last pressurized water reactor NPPs of western design in Europe, which has decided to replace the existing steam generators and at the same time perform a power uprating. A comprehensive set of design calculations and safety analyses have been performed to demonstrate: - that the new steam generators are compatible with the existing plant, - that the plant can operate safely and with adequate margins at the uprated power. In this paper only the mechanical and structural analyses are presented. These analyses meet, as verified by independent evaluations, high quality standards and ensure the safe operation of Krško NPP after the replacement of the steam generators and the power uprating.

integrity; mechanical analysis; structural analysis; leak before break (LBB);