Measurement Uncertainty in Calibration of Measurement Surface Plates Flatness

2140 Views
3949 Downloads
Export citation: ABNT
GUSEL, Andrej ;AČKO, Bojan ;MUDRONJA, Vedran .
Measurement Uncertainty in Calibration of Measurement Surface Plates Flatness. 
Strojniški vestnik - Journal of Mechanical Engineering, [S.l.], v. 55, n.5, p. 286-292, august 2017. 
ISSN 0039-2480.
Available at: <https://www.sv-jme.eu/article/measurement-uncertainty-in-calibration-of-measurement-surface-plates-flatness/>. Date accessed: 11 dec. 2024. 
doi:http://dx.doi.org/.
Gusel, A., Ačko, B., & Mudronja, V.
(2009).
Measurement Uncertainty in Calibration of Measurement Surface Plates Flatness.
Strojniški vestnik - Journal of Mechanical Engineering, 55(5), 286-292.
doi:http://dx.doi.org/
@article{.,
	author = {Andrej  Gusel and Bojan  Ačko and Vedran  Mudronja},
	title = {Measurement Uncertainty in Calibration of Measurement Surface Plates Flatness},
	journal = {Strojniški vestnik - Journal of Mechanical Engineering},
	volume = {55},
	number = {5},
	year = {2009},
	keywords = {production measurements; lenght measurements; measuring uncertainty; calibration; flatness measurement; },
	abstract = {A flat measurement surface e.g. a measurement plate, can be considered as the origin for performing most form and position measurements on measured objects. In order to use measurement plates in a proper way, it has to be assured that they are really flat and suitable for measurements. Flatness of measurement surface is determined indirectly  by measuring the straightness of individual lines that build up the measurement grid. These lines are further divided into measurement steps that suit the dimensions of measuring instruments. Straightness of a measurement line is calculated for each line separately by measuring inclination of each measurement position, whereas flatness deviation of the entire surface is determined by linking the results of separate lines. Backgrounds, procedures and measuring equipment for performing such measurement are well known, whilst the uncertainty of measurement surface calibration remains undetermined. Without properly expressed uncertainty, a measurement means all but nothing. Therefore, a determination of measurement uncertainty has to be assured.},
	issn = {0039-2480},	pages = {286-292},	doi = {},
	url = {https://www.sv-jme.eu/article/measurement-uncertainty-in-calibration-of-measurement-surface-plates-flatness/}
}
Gusel, A.,Ačko, B.,Mudronja, V.
2009 August 55. Measurement Uncertainty in Calibration of Measurement Surface Plates Flatness. Strojniški vestnik - Journal of Mechanical Engineering. [Online] 55:5
%A Gusel, Andrej 
%A Ačko, Bojan 
%A Mudronja, Vedran 
%D 2009
%T Measurement Uncertainty in Calibration of Measurement Surface Plates Flatness
%B 2009
%9 production measurements; lenght measurements; measuring uncertainty; calibration; flatness measurement; 
%! Measurement Uncertainty in Calibration of Measurement Surface Plates Flatness
%K production measurements; lenght measurements; measuring uncertainty; calibration; flatness measurement; 
%X A flat measurement surface e.g. a measurement plate, can be considered as the origin for performing most form and position measurements on measured objects. In order to use measurement plates in a proper way, it has to be assured that they are really flat and suitable for measurements. Flatness of measurement surface is determined indirectly  by measuring the straightness of individual lines that build up the measurement grid. These lines are further divided into measurement steps that suit the dimensions of measuring instruments. Straightness of a measurement line is calculated for each line separately by measuring inclination of each measurement position, whereas flatness deviation of the entire surface is determined by linking the results of separate lines. Backgrounds, procedures and measuring equipment for performing such measurement are well known, whilst the uncertainty of measurement surface calibration remains undetermined. Without properly expressed uncertainty, a measurement means all but nothing. Therefore, a determination of measurement uncertainty has to be assured.
%U https://www.sv-jme.eu/article/measurement-uncertainty-in-calibration-of-measurement-surface-plates-flatness/
%0 Journal Article
%R 
%& 286
%P 7
%J Strojniški vestnik - Journal of Mechanical Engineering
%V 55
%N 5
%@ 0039-2480
%8 2017-08-21
%7 2017-08-21
Gusel, Andrej, Bojan  Ačko, & Vedran  Mudronja.
"Measurement Uncertainty in Calibration of Measurement Surface Plates Flatness." Strojniški vestnik - Journal of Mechanical Engineering [Online], 55.5 (2009): 286-292. Web.  11 Dec. 2024
TY  - JOUR
AU  - Gusel, Andrej 
AU  - Ačko, Bojan 
AU  - Mudronja, Vedran 
PY  - 2009
TI  - Measurement Uncertainty in Calibration of Measurement Surface Plates Flatness
JF  - Strojniški vestnik - Journal of Mechanical Engineering
DO  - 
KW  - production measurements; lenght measurements; measuring uncertainty; calibration; flatness measurement; 
N2  - A flat measurement surface e.g. a measurement plate, can be considered as the origin for performing most form and position measurements on measured objects. In order to use measurement plates in a proper way, it has to be assured that they are really flat and suitable for measurements. Flatness of measurement surface is determined indirectly  by measuring the straightness of individual lines that build up the measurement grid. These lines are further divided into measurement steps that suit the dimensions of measuring instruments. Straightness of a measurement line is calculated for each line separately by measuring inclination of each measurement position, whereas flatness deviation of the entire surface is determined by linking the results of separate lines. Backgrounds, procedures and measuring equipment for performing such measurement are well known, whilst the uncertainty of measurement surface calibration remains undetermined. Without properly expressed uncertainty, a measurement means all but nothing. Therefore, a determination of measurement uncertainty has to be assured.
UR  - https://www.sv-jme.eu/article/measurement-uncertainty-in-calibration-of-measurement-surface-plates-flatness/
@article{{}{.},
	author = {Gusel, A., Ačko, B., Mudronja, V.},
	title = {Measurement Uncertainty in Calibration of Measurement Surface Plates Flatness},
	journal = {Strojniški vestnik - Journal of Mechanical Engineering},
	volume = {55},
	number = {5},
	year = {2009},
	doi = {},
	url = {https://www.sv-jme.eu/article/measurement-uncertainty-in-calibration-of-measurement-surface-plates-flatness/}
}
TY  - JOUR
AU  - Gusel, Andrej 
AU  - Ačko, Bojan 
AU  - Mudronja, Vedran 
PY  - 2017/08/21
TI  - Measurement Uncertainty in Calibration of Measurement Surface Plates Flatness
JF  - Strojniški vestnik - Journal of Mechanical Engineering; Vol 55, No 5 (2009): Strojniški vestnik - Journal of Mechanical Engineering
DO  - 
KW  - production measurements, lenght measurements, measuring uncertainty, calibration, flatness measurement, 
N2  - A flat measurement surface e.g. a measurement plate, can be considered as the origin for performing most form and position measurements on measured objects. In order to use measurement plates in a proper way, it has to be assured that they are really flat and suitable for measurements. Flatness of measurement surface is determined indirectly  by measuring the straightness of individual lines that build up the measurement grid. These lines are further divided into measurement steps that suit the dimensions of measuring instruments. Straightness of a measurement line is calculated for each line separately by measuring inclination of each measurement position, whereas flatness deviation of the entire surface is determined by linking the results of separate lines. Backgrounds, procedures and measuring equipment for performing such measurement are well known, whilst the uncertainty of measurement surface calibration remains undetermined. Without properly expressed uncertainty, a measurement means all but nothing. Therefore, a determination of measurement uncertainty has to be assured.
UR  - https://www.sv-jme.eu/article/measurement-uncertainty-in-calibration-of-measurement-surface-plates-flatness/
Gusel, Andrej, Ačko, Bojan, AND Mudronja, Vedran.
"Measurement Uncertainty in Calibration of Measurement Surface Plates Flatness" Strojniški vestnik - Journal of Mechanical Engineering [Online], Volume 55 Number 5 (21 August 2017)

Authors

Affiliations

  • Mariborska livarna Maribor, Slovenia
  • Faculty of Mechanical Enigneering, Maribor, Slovenia
  • Faculty of Mechanical Engineering and Naval Architecture, Zagreb, Croatia

Paper's information

Strojniški vestnik - Journal of Mechanical Engineering 55(2009)5, 286-292
© The Authors, CC-BY 4.0 Int. Change in copyright policy from 2022, Jan 1st.

A flat measurement surface e.g. a measurement plate, can be considered as the origin for performing most form and position measurements on measured objects. In order to use measurement plates in a proper way, it has to be assured that they are really flat and suitable for measurements. Flatness of measurement surface is determined indirectly  by measuring the straightness of individual lines that build up the measurement grid. These lines are further divided into measurement steps that suit the dimensions of measuring instruments. Straightness of a measurement line is calculated for each line separately by measuring inclination of each measurement position, whereas flatness deviation of the entire surface is determined by linking the results of separate lines. Backgrounds, procedures and measuring equipment for performing such measurement are well known, whilst the uncertainty of measurement surface calibration remains undetermined. Without properly expressed uncertainty, a measurement means all but nothing. Therefore, a determination of measurement uncertainty has to be assured.

production measurements; lenght measurements; measuring uncertainty; calibration; flatness measurement;