The Reduction of Nitrogen Oxide Emissions by the Boiler Firing System Reconstruction at the Power Plant Ljubljana

1892 Views
1465 Downloads
Export citation: ABNT
OMAN, Janez ;KUŠTRIN, Igor ;BOLE, Igor ;GOSTINČAR, Primož .
The Reduction of Nitrogen Oxide Emissions by the Boiler Firing System Reconstruction at the Power Plant Ljubljana. 
Strojniški vestnik - Journal of Mechanical Engineering, [S.l.], v. 51, n.5, p. 240-251, august 2017. 
ISSN 0039-2480.
Available at: <https://www.sv-jme.eu/article/the-reduction-of-nitrogen-oxide-emissions-by-the-boiler-firing-system-reconstruction-at-the-power-plant-ljubljana/>. Date accessed: 01 dec. 2024. 
doi:http://dx.doi.org/.
Oman, J., Kuštrin, I., Bole, I., & Gostinčar, P.
(2005).
The Reduction of Nitrogen Oxide Emissions by the Boiler Firing System Reconstruction at the Power Plant Ljubljana.
Strojniški vestnik - Journal of Mechanical Engineering, 51(5), 240-251.
doi:http://dx.doi.org/
@article{.,
	author = {Janez  Oman and Igor  Kuštrin and Igor  Bole and Primož  Gostinčar},
	title = {The Reduction of Nitrogen Oxide Emissions by the Boiler Firing System Reconstruction at the Power Plant Ljubljana},
	journal = {Strojniški vestnik - Journal of Mechanical Engineering},
	volume = {51},
	number = {5},
	year = {2005},
	keywords = {NOx; emission; combustion systems; efficiency; burners; },
	abstract = {In Slovenia, NOx emissions from boilers of 50 to 500 MW must be under 650 mg/m3 by the end of year 2007. Afterwards, the limit will be 600 mg/m3 . The emissions of the Power Plant Ljubljana have often exceeded the stated limiting values. After the reconstruction of the firing system of boiler 3, which was carried out using knowledge from abroad, it was necessary to reconstruct the firing systems of boilers 1 and 2, which remained the main sources of NOx and CO emissions. The reconstruction based on domestic knowledge was carried out by experts from the Power Plant Ljubljana and the Faculty of Mechanical Engineering, Ljubljana. The paper describes the essence of the reconstruction and its results. Besides lower emissions there was also a significant improvement in the efficiencies of the boilers.},
	issn = {0039-2480},	pages = {240-251},	doi = {},
	url = {https://www.sv-jme.eu/article/the-reduction-of-nitrogen-oxide-emissions-by-the-boiler-firing-system-reconstruction-at-the-power-plant-ljubljana/}
}
Oman, J.,Kuštrin, I.,Bole, I.,Gostinčar, P.
2005 August 51. The Reduction of Nitrogen Oxide Emissions by the Boiler Firing System Reconstruction at the Power Plant Ljubljana. Strojniški vestnik - Journal of Mechanical Engineering. [Online] 51:5
%A Oman, Janez 
%A Kuštrin, Igor 
%A Bole, Igor 
%A Gostinčar, Primož 
%D 2005
%T The Reduction of Nitrogen Oxide Emissions by the Boiler Firing System Reconstruction at the Power Plant Ljubljana
%B 2005
%9 NOx; emission; combustion systems; efficiency; burners; 
%! The Reduction of Nitrogen Oxide Emissions by the Boiler Firing System Reconstruction at the Power Plant Ljubljana
%K NOx; emission; combustion systems; efficiency; burners; 
%X In Slovenia, NOx emissions from boilers of 50 to 500 MW must be under 650 mg/m3 by the end of year 2007. Afterwards, the limit will be 600 mg/m3 . The emissions of the Power Plant Ljubljana have often exceeded the stated limiting values. After the reconstruction of the firing system of boiler 3, which was carried out using knowledge from abroad, it was necessary to reconstruct the firing systems of boilers 1 and 2, which remained the main sources of NOx and CO emissions. The reconstruction based on domestic knowledge was carried out by experts from the Power Plant Ljubljana and the Faculty of Mechanical Engineering, Ljubljana. The paper describes the essence of the reconstruction and its results. Besides lower emissions there was also a significant improvement in the efficiencies of the boilers.
%U https://www.sv-jme.eu/article/the-reduction-of-nitrogen-oxide-emissions-by-the-boiler-firing-system-reconstruction-at-the-power-plant-ljubljana/
%0 Journal Article
%R 
%& 240
%P 12
%J Strojniški vestnik - Journal of Mechanical Engineering
%V 51
%N 5
%@ 0039-2480
%8 2017-08-18
%7 2017-08-18
Oman, Janez, Igor  Kuštrin, Igor  Bole, & Primož  Gostinčar.
"The Reduction of Nitrogen Oxide Emissions by the Boiler Firing System Reconstruction at the Power Plant Ljubljana." Strojniški vestnik - Journal of Mechanical Engineering [Online], 51.5 (2005): 240-251. Web.  01 Dec. 2024
TY  - JOUR
AU  - Oman, Janez 
AU  - Kuštrin, Igor 
AU  - Bole, Igor 
AU  - Gostinčar, Primož 
PY  - 2005
TI  - The Reduction of Nitrogen Oxide Emissions by the Boiler Firing System Reconstruction at the Power Plant Ljubljana
JF  - Strojniški vestnik - Journal of Mechanical Engineering
DO  - 
KW  - NOx; emission; combustion systems; efficiency; burners; 
N2  - In Slovenia, NOx emissions from boilers of 50 to 500 MW must be under 650 mg/m3 by the end of year 2007. Afterwards, the limit will be 600 mg/m3 . The emissions of the Power Plant Ljubljana have often exceeded the stated limiting values. After the reconstruction of the firing system of boiler 3, which was carried out using knowledge from abroad, it was necessary to reconstruct the firing systems of boilers 1 and 2, which remained the main sources of NOx and CO emissions. The reconstruction based on domestic knowledge was carried out by experts from the Power Plant Ljubljana and the Faculty of Mechanical Engineering, Ljubljana. The paper describes the essence of the reconstruction and its results. Besides lower emissions there was also a significant improvement in the efficiencies of the boilers.
UR  - https://www.sv-jme.eu/article/the-reduction-of-nitrogen-oxide-emissions-by-the-boiler-firing-system-reconstruction-at-the-power-plant-ljubljana/
@article{{}{.},
	author = {Oman, J., Kuštrin, I., Bole, I., Gostinčar, P.},
	title = {The Reduction of Nitrogen Oxide Emissions by the Boiler Firing System Reconstruction at the Power Plant Ljubljana},
	journal = {Strojniški vestnik - Journal of Mechanical Engineering},
	volume = {51},
	number = {5},
	year = {2005},
	doi = {},
	url = {https://www.sv-jme.eu/article/the-reduction-of-nitrogen-oxide-emissions-by-the-boiler-firing-system-reconstruction-at-the-power-plant-ljubljana/}
}
TY  - JOUR
AU  - Oman, Janez 
AU  - Kuštrin, Igor 
AU  - Bole, Igor 
AU  - Gostinčar, Primož 
PY  - 2017/08/18
TI  - The Reduction of Nitrogen Oxide Emissions by the Boiler Firing System Reconstruction at the Power Plant Ljubljana
JF  - Strojniški vestnik - Journal of Mechanical Engineering; Vol 51, No 5 (2005): Strojniški vestnik - Journal of Mechanical Engineering
DO  - 
KW  - NOx, emission, combustion systems, efficiency, burners, 
N2  - In Slovenia, NOx emissions from boilers of 50 to 500 MW must be under 650 mg/m3 by the end of year 2007. Afterwards, the limit will be 600 mg/m3 . The emissions of the Power Plant Ljubljana have often exceeded the stated limiting values. After the reconstruction of the firing system of boiler 3, which was carried out using knowledge from abroad, it was necessary to reconstruct the firing systems of boilers 1 and 2, which remained the main sources of NOx and CO emissions. The reconstruction based on domestic knowledge was carried out by experts from the Power Plant Ljubljana and the Faculty of Mechanical Engineering, Ljubljana. The paper describes the essence of the reconstruction and its results. Besides lower emissions there was also a significant improvement in the efficiencies of the boilers.
UR  - https://www.sv-jme.eu/article/the-reduction-of-nitrogen-oxide-emissions-by-the-boiler-firing-system-reconstruction-at-the-power-plant-ljubljana/
Oman, Janez, Kuštrin, Igor, Bole, Igor, AND Gostinčar, Primož.
"The Reduction of Nitrogen Oxide Emissions by the Boiler Firing System Reconstruction at the Power Plant Ljubljana" Strojniški vestnik - Journal of Mechanical Engineering [Online], Volume 51 Number 5 (18 August 2017)

Authors

Affiliations

  • University of Ljubljana, Faculty of Mechanical Engineering, Slovenia
  • University of Ljubljana, Faculty of Mechanical Engineering, Slovenia
  • Termoelektrarna toplarna Ljubljana, Slovenia
  • Termoelektrarna toplarna Ljubljana, Slovenia

Paper's information

Strojniški vestnik - Journal of Mechanical Engineering 51(2005)5, 240-251
© The Authors, CC-BY 4.0 Int. Change in copyright policy from 2022, Jan 1st.

In Slovenia, NOx emissions from boilers of 50 to 500 MW must be under 650 mg/m3 by the end of year 2007. Afterwards, the limit will be 600 mg/m3 . The emissions of the Power Plant Ljubljana have often exceeded the stated limiting values. After the reconstruction of the firing system of boiler 3, which was carried out using knowledge from abroad, it was necessary to reconstruct the firing systems of boilers 1 and 2, which remained the main sources of NOx and CO emissions. The reconstruction based on domestic knowledge was carried out by experts from the Power Plant Ljubljana and the Faculty of Mechanical Engineering, Ljubljana. The paper describes the essence of the reconstruction and its results. Besides lower emissions there was also a significant improvement in the efficiencies of the boilers.

NOx; emission; combustion systems; efficiency; burners;